Transmission Line - Applicability

Applicability

In many electric circuits, the length of the wires connecting the components can for the most part be ignored. That is, the voltage on the wire at a given time can be assumed to be the same at all points. However, when the voltage changes in a time interval comparable to the time it takes for the signal to travel down the wire, the length becomes important and the wire must be treated as a transmission line. Stated another way, the length of the wire is important when the signal includes frequency components with corresponding wavelengths comparable to or less than the length of the wire.

A common rule of thumb is that the cable or wire should be treated as a transmission line if the length is greater than 1/10 of the wavelength. At this length the phase delay and the interference of any reflections on the line become important and can lead to unpredictable behavior in systems which have not been carefully designed using transmission line theory.

Read more about this topic:  Transmission Line

Other articles related to "applicability":

Quantitative Structure–activity Relationship - Application - Applications
... hull is generated by a particular training set of chemicals is called the training set's applicability domain ... of properties of novel chemicals that are located outside the applicability domain uses extrapolation, and so is less reliable (on average) than prediction within the applicability domain ...
Reliable Server Pooling - Standards Documents - Other Drafts
... Policy for Reliable Server Pooling Reliable Server Pooling Applicability for IP Flow Information Exchange Applicability of Reliable Server Pooling for Real-Time ...
Shape Factor (X-ray Diffraction) - Applicability
... It is important to realize that the Scherrer formula provides a lower bound on the particle size ... The reason for this is that a variety of factors can contribute to the width of a diffraction peak besides instrumental effects and crystallite size the most important of these are usually inhomogeneous strain and crystal lattice imperfections ...
Direct Applicability
... relates specifically to regulations, direct applicability (or the characteristic of regulations to be directly effective) is set out in Article 288 (ex Article 249) of the Treaty on the ... Although often confused with the doctrine of direct effect, direct applicability refers to the fact that regulations require no implementing legislation within ... governing regulations which provides that they, and only they, have direct applicability within the member states ...